Quick Mount's Low Slope Mount takes the traditional base-and-post PV mount to its ultimate level. It's the strongest you can buy for mechanically attaching commercial PV systems to TPO, PVC, EPDM, built-up asphalt, and virtually all other non-metal low slope roofs.
How to Flash Properly flashing penetrations in PVC, TPO and other membrane-type roofing requires the use of manufacturer-specific materials to ensure the flashing bonds chemically with the field membrane (ask your roofing supplier). For built up asphalt roofs (BUR) and other bituminous and modified bitumen roofs, Quick Mount includes aluminum cone flashings in its Low Slope Mount kits, one each fitted for use with the QBase and 6½" posts (17" x 17" x 4") and 8½" posts (17" x 17" x 8").
Features Code compliant for all non-metal low slope roofs QBase is the strongest off-the-shelf mechanical mount All exposed hardware stainless steel 3 post heights offer 7", 9" and 12" clearance off the deck Attaches to roof with 2 or 4 fasteners All fasteners and hardware included Mounts entire solar arrays Secures ballasted systems from shifting 100% IBC, UBC compliant Meets or exceeds all NRCA standards and practices 10-yr warranty; 50-yr expected life Works with all leading racks Great mount for solar hot water Patents pending
Parts and Materials Each mount kit (12 per box) includes: Cast aluminum QBase Two zinc-coated steel lag bolts, 5/16" x 3" Aluminum post, 1.25" x 6.5", 8.5" or 11.5" EPDM-bonded stainless steel sealing washer, 5/16" x 1-3/4" Stainless steel machine bolt, 5/16" x 1" Stainless steel fender washer, 5/16" x 1" Stainless steel split lock washer, 5/16" Grade-8 machine bolt, 5/16'' x 3/4''
Specifications Flashing size Flashing supplied only with Kits for built-up roofs - 17" x 17" Pullout/shear 3934 lbs. average pullout (Douglas fir); 4365 lbs. average shear (see engineering report) Tools needed for installation Tape measure Chalk line Caulking gun Roofing-compatible flashing and related waterproofing materials Drill with 1/4" bit Drill or impact gun with deep 1/2" socket
Applicable roof types TPO, PVC, EPDM; built-up asphalt, bituminous and modified bitumen; virtually all other non-metal low slope roofs